金狮贵宾会3420055

金狮贵宾会-宾至如归-尊贵-显赫 金狮贵宾会-宾至如归-尊贵-显赫

产品中心

金狮贵宾会-宾至如归-尊贵-显赫
金狮贵宾会-宾至如归-尊贵-显赫
金狮贵宾会-宾至如归-尊贵-显赫
一步法人基质金属卵白酶8(MMP8)酶联免疫吸附检测试剂盒
ELK070ES
金狮贵宾会-宾至如归-尊贵-显赫规格: 金狮贵宾会-宾至如归-尊贵-显赫价钱:
64T ¥1960.00
112T ¥2800.00

Overview

Product name: EasyStep Human MMP8(Matrix Metalloproteinase 8) ELISA Kit
Reactivity: Human
Alternative Names: CLG2; HNC; PMNL-CL; Collagenase 2; Neutrophil Collagenase; PMNL collagenase
Assay Type: Sandwich
Sensitivity: 24 pg/mL
Standard: 10 ng/mL
Detection Range: 0.16-10 ng/mL
Sample Type: Serum, plasma
Assay Length: 1.5h
Research Area: Enzyme & Kinase;Infection immunity;Cardiovascular biology;
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human MMP-8, and the Human MMP-8 standard plate wells that pre-coated using protein-related techniques are provided separately. Standard/Sample Diluent Buffer or samples are added to the appropriate microtiter plate wells ,then added a HRP-conjugated antibody specific to Human MMP-8. After TMB substrate solution is added, only those wells that contain Human MMP-8 and HRP-conjugated antibody will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human MMP-8 in the samples is then determined by comparing the OD of the samples to the standard curve.

标准曲线

Concentration (ng/mL) OD Corrected OD
10.00 2.231 2.127
5.00 1.697 1.593
2.50 1.069 0.965
1.25 0.752 0.648
0.63 0.451 0.347
0.32 0.352 0.248
0.16 0.228 0.124
0.00 0.104 0.000
金狮贵宾会-宾至如归-尊贵-显赫

细密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

接纳率

Matrices listed below were spiked with certain level of recombinant MMP-8 and the recovery rates were calculated by comparing the measured value to the expected amount of MMP-8 in samples.
Matrix Recovery range Average
serum(n=5) 87-99% 93%
EDTA plasma(n=5) 85-97% 91%
Heparin plasma(n=5) 90-103% 96%

线性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of MMP-8 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 85-92% 79-96% 92-101% 87-98%
EDTA plasma(n=5) 92-105% 82-92% 86-94% 81-95%
Heparin plasma(n=5) 86-93% 91-104% 87-98% 95-99%

产品因素表

关闭

在线咨询

Online consultation

  • 金狮贵宾会-宾至如归-尊贵-显赫 在线咨询
  • 金狮贵宾会-宾至如归-尊贵-显赫 手艺支持
金狮贵宾会-宾至如归-尊贵-显赫

关注微信公众号

金狮贵宾会-宾至如归-尊贵-显赫

微信扫一扫连忙咨询

微信电脑端咨询
金狮贵宾会-宾至如归-尊贵-显赫

微信扫一扫连忙咨询

微信电脑端咨询
关闭
网站地图
友情链接:尊龙凯时  918博天堂  皇冠hg1088  918博天堂  必一运动  z6com尊龙凯时代理  金狮贵宾会3420055  SG亚洲胜游  宝马娱乐网站bmw0002  尊龙官方入口  吕氏贵宾会  ka电子  云鼎国际4118  庄闲和游戏  WM真人WM视讯