金狮贵宾会3420055

金狮贵宾会-宾至如归-尊贵-显赫 金狮贵宾会-宾至如归-尊贵-显赫

产品中心

金狮贵宾会-宾至如归-尊贵-显赫
金狮贵宾会-宾至如归-尊贵-显赫
金狮贵宾会-宾至如归-尊贵-显赫
一步法人团结珠卵白(HP)酶联免疫吸附检测试剂盒
ELK077ES
金狮贵宾会-宾至如归-尊贵-显赫规格: 金狮贵宾会-宾至如归-尊贵-显赫价钱:
64T ¥1960.00
112T ¥2800.00

Overview

Product name: EasyStep Human HP(Haptoglobin) ELISA Kit
Reactivity: Human
Alternative Names: HP; Hp2-Alpha; Alpha-2-Macroglobulin; Zonulin; Hpt; Haptoglobin
Assay Type: Sandwich
Sensitivity: 0.02 ng/mL
Standard: 400 ng/mL
Detection Range: 6.25-400 ng/mL
Sample Type: Serum, plasma
Assay Length: 1.5h
Research Area: Infection immunity;Hematology;
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human HP, and the Human HP standard plate wells that pre-coated using protein-related techniques are provided separately. Standard/Sample Diluent Buffer or samples are added to the appropriate microtiter plate wells ,then added a HRP-conjugated antibody specific to Human HP. After TMB substrate solution is added, only those wells that contain Human HP and HRP-conjugated antibody will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human HP in the samples is then determined by comparing the OD of the samples to the standard curve.

标准曲线

Concentration (ng/mL) OD Corrected OD
400.00 1.997 1.912
200.00 1.629 1.544
100.00 1.194 1.109
50.00 0.971 0.886
25.00 0.509 0.424
12.50 0.364 0.279
6.25 0.219 0.134
0.00 0.085 0.000
金狮贵宾会-宾至如归-尊贵-显赫

细密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

接纳率

Matrices listed below were spiked with certain level of recombinant HP and the recovery rates were calculated by comparing the measured value to the expected amount of HP in samples.
Matrix Recovery range Average
serum(n=5) 80-95% 87%
EDTA plasma(n=5) 80-93% 86%
Heparin plasma(n=5) 95-107% 101%

线性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of HP and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 86-93% 91-105% 87-99% 99-105%
EDTA plasma(n=5) 88-95% 96-102% 89-103% 89-96%
Heparin plasma(n=5) 87-101% 87-96% 82-93% 89-97%

产品因素表

关闭

在线咨询

Online consultation

  • 金狮贵宾会-宾至如归-尊贵-显赫 在线咨询
  • 金狮贵宾会-宾至如归-尊贵-显赫 手艺支持
金狮贵宾会-宾至如归-尊贵-显赫

关注微信公众号

金狮贵宾会-宾至如归-尊贵-显赫

微信扫一扫连忙咨询

微信电脑端咨询
金狮贵宾会-宾至如归-尊贵-显赫

微信扫一扫连忙咨询

微信电脑端咨询
关闭
网站地图
友情链接:918博天堂  凯时人生就是搏  PP电子  美狮贵宾会  皇冠hg1088  威客电竞  vsport体育平台  庄闲和对子网站  pg赏金女王模拟器在线试玩  贝斯特全球最奢华  尊龙凯时  z6com尊龙凯时代理  庄闲和网址  庄闲和网址  维多利亚老品牌