金狮贵宾会3420055

金狮贵宾会-宾至如归-尊贵-显赫 金狮贵宾会-宾至如归-尊贵-显赫

产品中心

金狮贵宾会-宾至如归-尊贵-显赫
金狮贵宾会-宾至如归-尊贵-显赫
小鼠嗜酸粒细胞趋化因子(ECF)酶联免疫吸附检测试剂盒
ELK1010
金狮贵宾会-宾至如归-尊贵-显赫规格: 金狮贵宾会-宾至如归-尊贵-显赫价钱:
48T ¥1680.00
96T ¥2400.00

Overview

Product name: Mouse ECF(Eosinophil Chemotactic Factor) ELISA Kit
Reactivity: Mouse
Alternative Names: CCL11; SCYA11; Eotaxin 1; Eosinophil Chemotactic Protein 1; Chemokine C-C-Motif Ligand 11; Small Inducible Cytokine Subfamily A(Cys-Cys)Member 11
Assay Type: Sandwich
Sensitivity: 3.2 pg/mL
Standard: 500 pg/mL
Detection Range: 7.82-500 pg/mL
Sample Type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Cytokine;Infection immunity;Autoimmunity;
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Mouse ECF. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Mouse ECF. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Mouse ECF, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Mouse ECF in the samples is then determined by comparing the OD of the samples to the standard curve.

标准曲线

Concentration (pg/mL) OD Corrected OD
500.00 2.131 2.054
250.00 1.379 1.302
125.00 0.743 0.666
62.50 0.427 0.350
31.25 0.258 0.181
15.63 0.168 0.091
7.82 0.119 0.042
0.00 0.077 0.000
金狮贵宾会-宾至如归-尊贵-显赫

细密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

接纳率

Matrices listed below were spiked with certain level of recombinant ECF and the recovery rates were calculated by comparing the measured value to the expected amount of ECF in samples.
Matrix Recovery range Average
serum(n=5) 88-102% 95%
EDTA plasma(n=5) 79-97% 88%
Heparin plasma(n=5) 83-95% 89%

线性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of ECF and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 86-95% 82-93% 97-106% 89-102%
EDTA plasma(n=5) 78-91% 86-92% 89-96% 91-97%
Heparin plasma(n=5) 95-104% 97-105% 82-95% 89-97%
关闭

在线咨询

Online consultation

  • 金狮贵宾会-宾至如归-尊贵-显赫 在线咨询
  • 金狮贵宾会-宾至如归-尊贵-显赫 手艺支持
金狮贵宾会-宾至如归-尊贵-显赫

关注微信公众号

金狮贵宾会-宾至如归-尊贵-显赫

微信扫一扫连忙咨询

微信电脑端咨询
金狮贵宾会-宾至如归-尊贵-显赫

微信扫一扫连忙咨询

微信电脑端咨询
关闭
网站地图
友情链接:银河集团198net  韦德官网  沐鸣2  amjs澳金沙门  曾氏贵宾会  尊龙凯时  cq9电子  智博1919体育  维多利亚老品牌  韦德官网  杏鑫平台  美狮贵宾会  贝斯特全球最奢华  5357cc拉斯维加斯  yd2333云顶电子游戏