Overview

Product name: Human FAS(Factor Related Apoptosis) ELISA Kit
Reactivity: Human
Alternative Names: CD95; ALPS1A; ALPS1-A; APO1; APT1; FAS1; FASTM; TNFRSF6; Fas Receptor; TNF Receptor Superfamily Member 6; Tumor Necrosis Factor Receptor Superfamily Member 6
Assay Type: Sandwich
Sensitivity: 15 pg/mL
Standard: 2500 pg/mL
Detection Range: 39.07-2500 pg/mL
Sample Type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Apoptosis;Tumor immunity;
Uniprot ID: P25445
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human FAS. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human FAS. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human FAS, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human FAS in the samples is then determined by comparing the OD of the samples to the standard curve.

标准曲线

Concentration (pg/mL) OD Corrected OD
2500.00 2.172 2.064
1250.00 1.608 1.500
625.00 1.106 0.998
312.50 0.835 0.727
156.25 0.539 0.431
78.13 0.384 0.276
39.07 0.226 0.118
0.00 0.108 0.000
金狮贵宾会-宾至如归-尊贵-显赫

细密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

接纳率

Matrices listed below were spiked with certain level of recombinant FAS and the recovery rates were calculated by comparing the measured value to the expected amount of FAS in samples.
Matrix Recovery range Average
serum(n=5) 88-96% 92%
EDTA plasma(n=5) 95-107% 101%
Heparin plasma(n=5) 81-95% 88%

线性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of FAS and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 85-94% 93-101% 87-98% 89-102%
EDTA plasma(n=5) 97-105% 88-95% 96-102% 83-97%
Heparin plasma(n=5) 89-103% 85-93% 89-97% 95-102%